Home › Gutter size

Gutter and downpipe size checker

In short

  • Pick the roof pitch and type in the size of the roof that drains to one outlet.
  • It gives the smallest half-round gutter and outlet from Approved Document H.
  • The downpipe should be at least as big as the outlet.
1. What kind of roof?

Between two pitches? Pick the steeper one.

2. Length of the roof slope along the gutter, on plan
metres
3. Depth of the roof slope, on plan

From the gutter to the ridge, measured flat (as on the drawing), not up the slope.

metres
4. Where is the outlet?
Gutter 100mm / outlet 63mm

Where this comes from

  • Approved Document H3, Table 1: effective area = plan area (flat), × 1.29 (30°), × 1.50 (45°), × 1.87 (60°).
  • H3 Table 2 (level half-round gutter, sharp-edged outlet at one end): up to 18m² 75mm gutter / 50mm outlet; 37m² 100mm / 63mm; 53m² 115mm / 63mm; 65m² 125mm / 75mm; 103m² 150mm / 89mm.
  • H3 1.5: with the outlet not at the end, size the gutter for the larger of the areas draining to it. H3 1.10: the rainwater pipe at least the size of the outlet.
  • Rainfall varies across the country (H3 Diagram 1). Valley, parapet and flat-roof systems where overflow would get into the building need a BS EN 12056 design (H3 1.2).

Guide only, not a certified design. Figures from Approved Document H (2015 edition). Building control, or your designer, has the final say. Nothing you type here is sent anywhere.