Home › Soakaway vs drainage field

Soakaway vs drainage field

In short

  • A rainwater soakaway installed after December 2007 doesn't meet the rules for septic tank effluent.
  • Effluent going to ground should go through a drainage field built to BS 6297.
  • Emptying the tank buys time but won't fix a failing drainage field.

Many older septic tanks drain into what everyone calls a soakaway. The rules now draw a sharp line between a rainwater-style soakaway and a properly designed drainage field. Here is why, and what it means for you.

Last checked against GOV.UK: 20 November 2026 · England
England only. These rules apply in England. Wales, Scotland and Northern Ireland have their own rules (for example Natural Resources Wales and SEPA). This guide is general information, not legal advice.

What is the difference?

SoakawayDrainage field (infiltration system)
What it isA pit or crate filled with rubble or a plastic unit, designed to let rainwater soak away at one pointA network of perforated pipes laid in gravel-filled trenches, spreading effluent over a wide area of soil
TreatmentLittle or none: effluent arrives at one spotThe soil does further treatment as the liquid trickles through
Under the general binding rulesA soakaway installed after December 2007 does not meet the rulesThe standard way to discharge septic tank or plant effluent to ground; must meet British Standard BS 6297

What GOV.UK says

For discharges to ground, you must use a septic tank or small sewage treatment plant and then discharge through a drainage field. You cannot meet the general binding rules if you use a well or borehole, or a soakaway designed for draining rainwater that was installed after December 2007.

GOV.UK also says non-standard structures such as boreholes, shafts and concrete rings are not usually appropriate for new discharges, and if effluent goes directly into groundwater through one of them, the Environment Agency will not grant a permit and the system must be replaced.

Drainage mounds, and engineered ground with a minimum percolation value of 15, can also meet the rules if they are outside floodplains and built in line with BS 6297.

My soakaway was installed before 2008. Am I fine?

The specific soakaway exclusion applies to soakaways installed after December 2007. An older system still has to meet all of the other rules that apply, including not causing pollution. If it is failing (waterlogged ground, smells, effluent at the surface, or the tank backing up), it needs looking at whatever its age.

Signs your drainage field or soakaway is failing

  • The level in the tank or outlet chamber stays high soon after an empty.
  • Wet, boggy or very green ground over the drainage area, or effluent at the surface.
  • Smells in the garden, and drains slow or backing up in the house.

Emptying the tank buys time, but it does not fix a drainage field that cannot take water away. Common causes include solids carried over from a tank that was not emptied often enough, a collapsed or blocked pipe, roots, or ground that was never suitable.

Replacing it: what is involved

  • A percolation test to measure how fast the ground drains. Approved Document H (building regulations) sets out how this is done and how to size the field, and says drainage fields are only suitable where the average percolation value is between 12 and 100 seconds per millimetre.
  • Siting. Approved Document H recommends keeping a drainage field at least 10 metres from any watercourse, at least 50 metres from a point where groundwater is taken for supply, and at least 15 metres from any building.
  • Building regulations approval, and planning permission where needed.
  • If the ground will not drain well enough, a treatment plant discharging to a flowing watercourse may be the alternative. See septic tank or treatment plant.

Common questions

Is a soakaway allowed for a septic tank?
A soakaway designed for rainwater and installed after December 2007 does not meet the general binding rules. Septic tank effluent going to ground should go through a drainage field that meets British Standard BS 6297.
What is a drainage field?
A series of perforated pipes laid in trenches so that effluent trickles through the soil for further treatment. GOV.UK also calls it an infiltration system.
Will emptying my tank fix a waterlogged soakaway?
Only for a while. It creates room in the tank, but if the drainage field cannot take water away it needs investigating and possibly replacing.

Sources

Related guides